Skip to content
s-multimeter

Banks

Client Request

Bank monitoring of total or partial power consumptions, active energy, reactive energy, consumption, tension and PF on single-phase and three-phase loads. Automated drives of the thermoregulation and lighting system.

Environmental monitoring within the branch. Direct reading of the Enel meter.

Intervention

Non-invasive installation of S-MultiMeter for electrical measurement of the three-phase loads with the use of openable CTs. With S-MultiMeter independent drives  forecast by connectig the modules output to the existing contactors.

On/off switching timing of specific loads.

Activation and timing on the entire air conditioning system such as pumps, condensing units, refrigerators, fan-coil…

Monitoring of the internal and also external temperature, brightness, relative humidity, atmospheric pressure in the branch with S-Sensor, which also allow the manual switching of the lights after hours.

Direct reading of the Enel electric meter to measure the total absorption of the office using the S-Meter.

Use of the Smart Thermostat function to optimize especially the heating and air conditioning system consumption. Thanks to the intelligent algorithm, the Canavisia self-learning system calculates the thermal response of the building at certain internal and external temperatures and on the basis of this calculation allows you to set the desired temperature at the desired time, preventing unnecessary advances on ignition or unpleasant delays.

In order to use of the Self-adaptive constant brightness function to set the intensity of the lighting bodies according to the brightness coming from outside, ensuring the necessary brightness but preventing unnecessary switchings. It is sufficient to set a desired brightness level and the system will automatically take care of maintaining the desired level by modifying the intensity of the lamps.

Automatic switching off of lights, air conditioners and modification of the heating set-pointwhen the alarm is armed.

Automatic switching of the lights when the alarm is disarmed.

s-multimeter

Client Benefits

  • Identification in particular of waste through precise, calibratable and also non-invasive monitoring integrated in particular with pre-existing facility management software.

  • Possibility of preparing specific corrective actions for the improvement of buildings and their yield in terms of comfort and consumption, based on the bank monitoring consumption.

  • Possibility to monitor firstly data locally and secondly remotely and through a predictive and especially punctual analysis to anticipate situations that are not compliant by optimizing the number of maintenance operations.

  • Energy wastage identification.

Case study

Other Projects

arredi urbani

Energy Monitoring and Tourism Promotion in a Municipality of Canavese

The project is aimed to evaluate the benefits obtained from the public lighting redevelopment plan in terms of lower consumption, savings, safety, quality e, enhancement of the heritage and of
monitoraggio energia elettrica

Monitoring of the Gas and Energy consumption of Public Offices

Energy field monitoring: three-way multimeter connected via 485 bus to LoRa antenna